| Customization: | Available |
|---|---|
| After-sales Service: | Yes |
| Warranty: | 5/10years |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency


|
Models
|
80K
|
100K
|
125K
|
|
Input DC (PV side)
|
|||
|
Recommended max. PV array size
|
160 kW
|
200 kW
|
250 kW
|
|
Max. usable PV input power
|
160 kW
|
200 kW
|
250 kW
|
|
Max. input voltage
|
1000 V
|
||
|
Rated voltage
|
600 V
|
||
|
Start-up voltage
|
180 V
|
||
|
MPPT voltage range
|
150 - 950 V
|
||
|
Max. input current
|
10 × 42 A
|
||
|
Max. short circuit current
|
10 × 60 A
|
||
|
MPPT number / Max. input strings number
|
10 / 20
|
||
|
Battery
|
|||
|
Battery type
|
Li-ion
|
||
|
Battery voltage range
|
300 - 950 V
|
||
|
Max. charge / discharge current
|
200 A / 100 A + 100 A
|
||
|
Number of battery ports
|
2
|
||
|
Max. charge / discharge current of each port
|
100 A
|
||
|
Communication
|
CAN / RS485
|
||
|
Output AC (Grid side)
|
|||
|
Rated output power
|
80 kW
|
100 kW
|
125 kW
|
|
Max. apparent output power
|
80 kVA
|
100 kVA
|
125 kVA
|
|
Rated grid voltage
|
3/N/PE, 220 V / 380 V, 230 V / 400 V
|
||
|
Rated grid frequency
|
50 Hz / 60 Hz
|
||
|
Rated grid output current
|
121.6 A / 115.5 A
|
152 A / 144.3 A
|
189.9 A / 180.4 A
|
|
Power factor
|
> 0.99 (0.8 leading - 0.8 lagging)
|
||
|
THDi
|
< 3%
|
||
|
Input AC (Grid side)
|
|||
|
Max. input current
|
250 A
|
||
|
Output AC (Back-up)
|
|||
|
Rated output power
|
80 kW
|
100 kW
|
125 kW
|
|
Max. apparent output power |
1.2 times of rated power, 10 mins; 1.4 times of rated power, 100 s;
1.6 times of rated power, 10 s; 2 times of rated power, 200 ms
|
1.2 times of rated power, 100 s;
1.4 times of rated power, 10 s;
1.6 times of rated power, 200 ms
|
|
|
Back-up switch time
|
< 10 ms
|
||
|
Rated output voltage
|
3/N/PE, 220 V / 380 V, 230 V / 400 V
|
||
|
Rated frequency
|
50 Hz / 60 Hz
|
||
|
THDv (@linear load)
|
< 2%
|
||
|
Input AC (Generator)
|
|||
|
Max. input power
|
80 kW
|
100 kW
|
125 kW
|
|
Rated input current
|
121.6 A / 115.5 A
|
151.9 A / 144.3 A
|
189.9 A / 180.4 A
|
|
Rated input voltage
|
3/N/PE, 220 V / 380 V; 3/N/PE, 230 V / 400 V
|
||
|
Rated input frequency
|
50 Hz / 60 Hz
|
||
|
Efficiency
|
|||
|
Max. efficiency
|
97.6%
|
||
|
EU efficiency
|
97.2%
|
||
|
BAT charged / discharged to AC max. efficiency
|
97.0%
|
||
|
Protection
|
|||
|
Anti-islanding protection
|
Yes
|
||
|
Output over current protection
|
Yes
|
||
|
Short circuit protection
|
Yes
|
||
|
Integrated DC switch
|
Yes
|
||
|
DC reverse-polarity protection
|
Yes
|
||
|
Surge protection
|
DC Type II / AC Type II
|
||
|
Integrated AFCI 2.0
|
Optional
|
||
|
Protection class / Over voltage category
|
I/ DC II, AC III
|
||
|
General Data
|
|||
|
Max. allowable phase imbalance (grid & back-up)
|
100%
|
||
|
Max. power per phase (grid & back-up)
|
26.66 kW
|
33.33 kW
|
41.66 kW
|
|
Dimensions (W × H × D)
|
1174 × 814 × 400 mm
|
||
|
Weight
|
170 kg
|
||
|
Topology
|
Transformerless
|
||
|
Operating ambient temperature range
|
-25 ~ +60°C
|
||
|
Relative humidity
|
0 - 100%
|
||
|
Ingress protection
|
IP66
|
||
|
Cooling concept
|
Intelligent fan-cooling
|
||
|
Max. operation altitude
|
3000 m
|
||
|
Grid connection standard |
G99, VDE-AR-N 4105/VDE V 0124, EN 50549-1&2/EN 50549-10, VDE 0126/UTE C 15/VFR:2019, NTS 631/RD 1699/RD 244/ UNE 206006/UNE
206007-1, CEI 0-21, C10/11, NRS 097-2-1, TOR, EIFS 2018.2, IEC 62116, IEC 61727, IEC 60068, IEC 61683,
EN 50530, MEA, PEA,PORTARIA Nº 140, DE 21 DE MARÇO DE 2022
|
||
|
Safety / EMC standard
|
IEC/EN 62109-1/-2, IEC/EN 61000-6-2/-4, EN 55011
|
||
|
Features
|
|||
|
PV connection
|
MC4 Quick connection plug
|
||
|
Battery connection
|
Terminal connector
|
||
|
AC connection
|
Terminal block
|
||
|
Display
|
7.0" LCD display & Bluetooth + APP
|
||
|
Communication
|
CAN, RS485-115200, Ethernet, Optional: Wi-Fi, Cellular, LAN
|
||