Customization: | Available |
---|---|
After-sales Service: | Yes |
Warranty: | 5/10years |
Still deciding? Get samples of US$ 279/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model Name
|
700-4G
|
1000-4G
|
1500-4G
|
2000-4G
|
2500-4G
|
3000-4G
|
3600-4G
|
Input DC
|
|||||||
Recommended max. PV power
|
0.9kW
|
1.2kW
|
1.8kW
|
2.3kW
|
3kW
|
3.5kW
|
4kW
|
Max. input voltage
|
600V
|
||||||
Rated voltage
|
200V
|
330V
|
|||||
Start-up voltage
|
60V
|
90V
|
|||||
MPPT voltage range
|
50-500V
|
80-500V
|
|||||
Max. input current
|
11A
|
19A
|
|||||
Max. short circuit current
|
17.2A
|
30A
|
|||||
MPPT number/Max. input strings number
|
1/1
|
1/2
|
|||||
Output AC
|
|||||||
Rated output power
|
0.7kW
|
1kW
|
1.5kW
|
2kW
|
2.5kW
|
3kW
|
3.6kW
|
Max. apparent output power
|
0.8kVA
|
1.1kVA
|
1.7kVA
|
2.2kVA
|
2.8kVA
|
3.3kVA
|
3.6kVA
|
Max. output power
|
0.8kW
|
1.1kW
|
1.7kW
|
2.2kW
|
2.8kW
|
3.3kW
|
3.6kW
|
Rated grid voltage
|
1/N/PE, 220/230V
|
||||||
Rated grid frequency
|
50/60Hz
|
||||||
Rated grid output current
|
3.2A/3.0A
|
4.5A/4.3A
|
6.8A/6.5A
|
9.1A/8.7A
|
11.4A/10.9A
|
13.6A/13A
|
16A
|
Max. output current
|
4.4A
|
5.2A
|
8.1A
|
10.5A
|
13.3A
|
15.7A
|
16A
|
Power Factor
|
>0.99 (0.8 leading - 0.8 lagging)
|
||||||
THDi
|
<3%
|
||||||
Efficiency
|
|||||||
Max. efficiency
|
97.2%
|
97.5%
|
|||||
EU efficiency
|
96.5%
|
96.8%
|
|||||
Protection
|
|||||||
DC reverse-polarity protection
|
Yes
|
||||||
Short circuit protection
|
Yes
|
||||||
Output over current protection
|
Yes
|
||||||
Surge protection
|
Yes
|
||||||
Grid monitoring
|
Yes
|
||||||
Anti-islanding protection
|
Yes
|
||||||
Temperature protection
|
Yes
|
||||||
Integrated DC switch
|
Optional
|
||||||
General Data
|
|||||||
Dimensions (W*H*D)
|
310*373*160 mm
|
||||||
Weight
|
7.4kg
|
7.7kg
|
|||||
Topology
|
Transformerless
|
||||||
Self consumption
|
<1W (night)
|
||||||
Operating ambient temperature range
|
-25 ~ +60°C
|
||||||
Relative humidity
|
0-100%
|
||||||
Ingress protection
|
IP65
|
||||||
Cooling concept
|
Natural convection
|
||||||
Max. operation altitude
|
4000m
|
||||||
Grid connection standard
|
VDE-AR-N 4105, VDE V 0124, VDE V 0126-1-1, UTE C15-712-1, NRS 097-1-2, G98, G99, EN 50549-1/-2, RD 1699, UNE 206006, UNE 206007-1,
IEC 61727
|
||||||
Safety/EMC standard
|
IEC 62109-1/-2, IEC 62116, EN 61000-6-1/-2/-3/-4
|
||||||
Features
|
|||||||
DC connection
|
MC4 connector
|
||||||
AC connection
|
Quick connection plug
|
||||||
Display
|
LCD
|
||||||
Communication
|
RS485, Optional: Wi-Fi, GPRS
|
Models
|
2.5K
|
3K
|
3.6K
|
4K
|
4.6K
|
5K
|
6K
|
Input DC
|
|||||||
Recommended max. PV power
|
3kW
|
3.5kW
|
4.2kW
|
4.6kW
|
5.3kW
|
5.8kW
|
6.6kW
|
Max. input voltage
|
550V
|
600V
|
|||||
Rated voltage
|
250V
|
330V
|
|||||
Start-up voltage
|
60V
|
120V
|
|||||
MPPT voltage range
|
50-450V
|
90-520V
|
|||||
Max. input current
|
11A/11A
|
||||||
Max. short circuit current
|
17.2A/17.2A
|
||||||
MPPT number/Max. input strings number
|
2/2
|
||||||
Output AC
|
|||||||
Rated output power
|
2.5kW
|
3kW
|
3.6kW
|
4kW
|
4.6kW
|
5kW
|
6kW
|
Max. apparent output power
|
2.8kVA
|
3.3kVA
|
4kVA
|
4.4kVA
|
5kVA
|
5kVA
|
6kVA
|
Max. output power
|
2.8kW
|
3.3kW
|
4kW
|
4.4kW
|
5kW
|
5kW
|
6kW
|
Rated grid voltage
|
1/N/PE, 220/230V
|
||||||
Rated grid frequency
|
50/60Hz
|
||||||
Rated grid output current
|
11.4A/10.9A
|
13.6A/13.0A
|
16.0A/15.7A
|
18.2A/17.4A
|
20.9A/20.0A
|
22.7A/21.7A
|
27.3A
|
Max. output current
|
13.3A
|
15.7A
|
16.0A
|
21.0A
|
23.8A
|
25.0A
|
27.3A
|
Power Factor
|
>0.99 (0.8 leading - 0.8 lagging)
|
||||||
THDi
|
<3%
|
||||||
Efficiency
|
|||||||
Max. efficiency
|
97.8%
|
98.1%
|
|||||
EU efficiency
|
97.1%
|
97.3%
|
|||||
Protection
|
|||||||
DC reverse-polarity protection
|
Yes
|
||||||
Short circuit protection
|
Yes
|
||||||
Output over current protection
|
Yes
|
||||||
Surge protection
|
Yes
|
||||||
Grid monitoring
|
Yes
|
||||||
Anti-islanding protection
|
Yes
|
||||||
Temperature protection
|
Yes
|
||||||
Integrated DC switch
|
Optional
|
||||||
General Data
|
|||||||
Dimensions (W*H*D)
|
310*543*160 mm
|
||||||
Weight
|
11.5kg
|
||||||
Topology
|
Transformerless
|
||||||
Self consumption
|
<1W (night)
|
||||||
Operating ambient temperature range
|
-25 ~ +60°C
|
||||||
Relative humidity
|
0-100%
|
||||||
Ingress protection
|
IP65
|
||||||
Cooling concept
|
Natural convection
|
||||||
Max. operation altitude
|
4000m
|
||||||
Grid connection standard
|
VDE-AR-N 4105, VDE V 0124, VDE V 0126-1-1, UTE C15-712-1, NRS 097-1-2, G98, G99, EN 50549-1/-2, RD 1699, UNE 206006, UNE 206007-1, IEC 61727
|
||||||
Safety/EMC standard
|
IEC 62109-1/-2, IEC 62116, EN 61000-6-2/-3
|
||||||
Features
|
|||||||
DC connection
|
MC4 connector
|
||||||
AC connection
|
Quick connection plug
|
||||||
Display
|
LCD
|
||||||
Communication
|
RS485, Optional: Wi-Fi, GPRS
|
||||||
Communication
|
RS485, Optional: Wi-Fi, GPRS
|
Models
|
7K
|
8K
|
9K
|
10K
|
Input DC
|
||||
Recommended max. PV power
|
10.5 kW
|
12 kW
|
13.5 kW
|
15 kW
|
Max. input voltage
|
600 V
|
|||
Rated voltage
|
330 V
|
|||
Start-up voltage
|
120 V
|
|||
MPPT voltage range
|
100-500 V
|
|||
Max. input current
|
14 A / 14 A / 14 A
|
|||
Max. short circuit current
|
22 A / 22 A / 22 A
|
|||
MPPT number/Max. input strings number
|
3 / 3
|
|||
Output AC
|
||||
Rated output power
|
7 kW
|
8 kW
|
9 kW
|
10 kW
|
Max. apparent output power
|
7.7 kVA
|
8.8 kVA
|
9.9 kVA
|
10 kVA
|
Max. output power
|
7.7 kW
|
8.8 kW
|
9.9 kW
|
10 kW
|
Rated grid voltage
|
1/N/PE, 220 V / 230 V
|
|||
Rated grid frequency
|
50 Hz / 60 Hz
|
|||
Rated grid output current
|
31.8 A / 30.4 A
|
36.4 A / 34.8 A
|
40.9 A / 39.1 A
|
45.5 A / 43.5 A
|
Max. output current
|
33.7 A
|
36.6 A
|
41.3 A
|
45.9 A
|
Power factor
|
>0.99 (0.8 leading - 0.8 lagging)
|
|||
THDi
|
<3%
|
|||
Efficiency
|
||||
Max. efficiency
|
98.0%
|
|||
EU efficiency
|
97.1%
|
|||
Protection
|
||||
DC reverse-polarity protection
|
Yes
|
|||
Short circuit protection
|
Yes
|
|||
Output over current protection
|
Yes
|
|||
Surge protection
|
Yes
|
|||
Grid monitoring
|
Yes
|
|||
Anti-islanding protection
|
Yes
|
|||
Temperature protection
|
Yes
|
|||
Integrated AFCI (DC arc-fault circuit protection)
|
Yes (1)
|
|||
Integrated DC switch
|
Optional
|
|||
General Data
|
||||
Dimensions (W*H*D)
|
333*579*253 mm
|
|||
Weight
|
18.5 kg
|
|||
Topology
|
Transformerless
|
|||
Self-consumption (night)
|
<1 W
|
|||
Operating ambient temperature range
|
-25 ~ +60°C
|
|||
Relative humidity
|
0-100%
|
|||
Ingress protection
|
IP66
|
|||
Cooling concept
|
Natural convection
|
|||
Max. operation altitude
|
4000 m
|
|||
Grid connection standard
|
G99, EN 50549-1, IEC 62116, IEC 61727, IEC60068, IEC 61683, EN 50530
|
|||
Safety/EMC standard
|
IEC/EN 62109-1/-2, IEC/EN 61000-6-1/-2/-3/-4
|
|||
Features
|
||||
DC connection
|
MC4 connector
|
|||
AC connection
|
OT Terminal
|
|||
Display
|
LCD
|
|||
Communication
|
RS485, Optional: Wi-Fi, GPRS
|
Models
|
3K
|
4K
|
5K
|
6K
|
8K
|
10K
|
12K
|
15K
|
20K
|
Input DC
|
|||||||||
Recommended max. PV power
|
4.5 kW
|
6 kW
|
7.5 kW
|
9 kW
|
12 kW
|
15 kW
|
18 kW
|
22.5 kW
|
30 kW
|
Max. input voltage
|
1100 V
|
||||||||
Rated voltage
|
600 V
|
||||||||
Start-up voltage
|
180 V
|
||||||||
MPPT voltage range
|
160-1000 V
|
||||||||
Max. input current
|
16 A / 16 A
|
32 A / 32 A
|
|||||||
Max. short circuit current
|
20 A / 20 A
|
40 A / 40 A
|
|||||||
MPPT number/Max. input strings number
|
2/2
|
2/4
|
|||||||
Output AC
|
|||||||||
Rated output power
|
3 kW
|
4 kW
|
5 kW
|
6 kW
|
8 kW
|
10 kW
|
12 kW
|
15 kW
|
20 kW
|
Max. apparent output power
|
3.3 kVA
|
4.4 kVA
|
5.5 kVA
|
6.6 kVA
|
8.8 kVA
|
11 kVA
|
13.2 kVA
|
16.5 kVA
|
22 kVA
|
Max. output power
|
3.3 kW
|
4.4 kW
|
5.5 kW
|
6.6 kW
|
8.8 kW
|
11 kW
|
13.2 kW
|
16.5 kW
|
22 kW
|
Rated grid voltage
|
3/N/PE, 220 V / 380 V, 230 V / 400 V
|
||||||||
Rated grid frequency
|
50 Hz / 60 Hz
|
||||||||
Rated grid output current
|
4.6 A /
4.3 A
|
6.1 A /
5.8 A
|
7.6 A /
7.2 A
|
9.1 A /
8.7 A
|
12.2 A /
11.5 A
|
15.2 A /
14.4 A
|
18.2 A /
17.3 A
|
22.8 A /
21.7 A
|
30.4 A /
28.9 A
|
Max. output current
|
4.7 A
|
6.4 A
|
7.9 A
|
9.5 A
|
12.7 A
|
15.9 A
|
19.1 A
|
23.8 A
|
31.8 A
|
Power factor
|
>0.99 (0.8 leading - 0.8 lagging)
|
||||||||
THDi
|
<2%
|
||||||||
Efficiency
|
|||||||||
Max. efficiency
|
98.3%
|
98.5%
|
98.6%
|
98.7%
|
|||||
EU efficiency
|
97.7%
|
97.9%
|
98.0%
|
98.1%
|
|||||
Protection
|
|||||||||
DC reverse-polarity protection
|
Yes
|
||||||||
Short circuit protection
|
Yes
|
||||||||
Output over current protection
|
Yes
|
||||||||
Surge protection
|
Yes
|
||||||||
Grid monitoring
|
Yes
|
||||||||
Anti-islanding protection
|
Yes
|
||||||||
Temperature protection
|
Yes
|
||||||||
Integrated AFCI (DC arc-fault circuit protection)
|
Yes (1)
|
||||||||
Integrated DC switch
|
Optional
|
||||||||
General Data
|
|||||||||
Dimensions (W*H*D)
|
310*563*219 mm
|
||||||||
Weight
|
17.8 kg
|
18.8 kg
|
20 kg
|
||||||
Topology
|
Transformerless
|
||||||||
Self-consumption (night)
|
<1 W
|
||||||||
Operating ambient temperature range
|
-25 ~ +60°C
|
||||||||
Relative humidity
|
0-100%
|
||||||||
Ingress protection
|
IP66
|
||||||||
Cooling concept
|
Natural convection
|
Intelligent redundant fan-cooling
|
|||||||
Max. operation altitude
|
4000 m
|
||||||||
Grid connection standard
|
G99, VDE-AR-N 4105 / VDE V 0124, EN 50549-1, VDE 0126 / UTE C 15 / VFR:2019, RD 1699 / RD 244 / UNE 206006 /
UNE 206007-1, CEI 0-21, C10/11, NRS 097-2-1, EIFS 2018.2, IEC 62116, IEC 61727, IEC 60068, IEC 61683, EN 50530
|
||||||||
Safety/EMC standard
|
IEC/EN 62109-1/-2, IEC/EN 61000-6-1/-2/-3/-4
|
||||||||
Features
|
|||||||||
DC connection
|
MC4 connector
|
||||||||
AC connection
|
Quick connection plug
|
||||||||
Display
|
LCD
|
||||||||
Communication
|
RS485, Optional: Wi-Fi, GPRS
|